Home FAQs e-Store Versions What's New

Home | FAQs | e-Store | Versions | What's New

VERSION DETAILS

 

Any new versions will be listed here along with previous versions and details of the changes made.  Here you may also find downloads for support files such as drivers and manuals.


 

Critical Issues:


 

Symptom: Key was registered now is not

CAUSE: Some versions of Windows are affected by Time changes or corrections, possibly interacting with virus scanners such as AVAST

 

CORRECTION: Apply the update.  We changed the registration model to a license file type model that no longer is sensitive to system time settings.

Update to 1.1.0.19 or later

For OBD-II update to 1.2.0.9 or later

 


Symptom: Incorrect Parameter errors

CAUSE: Engine Make data sent from computer is not in the expected format

CORRECTION: Apply the update 1.0.9.24 or later


Symptom: Database Errors after Upgrade

CAUSE: Windows blocked the database from being updated during the upgrade

CORRECTION:

Go to C:\Program Files\Pocketfleet\PFDiagnose

Delete the file PID.mdb

Re-apply the update by selecting the repair option


Symptom: IHC Body codes are incorrect or cause lockups

CAUSE: Byte 7 and 8 are used when not recommended by SAE

CORRECTION:

Contact for a copy of 1.1.0.10 v this version is expected to be released in September  2010


Symptom: J1939 locks up, Red TX light on

CAUSE: Error in Monitor screen code

CORRECTION:

Upgrade to 1.1.0.17b or later


 


Product:                     PF-Diagnose, Heavy Diesel Diagnostic Software

File Date:                   August 11, 2011  

Primary Version:        1.1

Sub Version:               0 . 19

Upgrade Type:              Update

COMPATIBILITY:       Windows XP, Vista, Windows 7

Note: Compatibility is for PF-Diagnose only, Third party software such as Device drivers for protocol adapters may not be compatible therefore you must confirm that they too will meet the software requirements.  All device drivers and Software are currently Windows XP service pack three. 

Downloads

Hit Counter

UPDATES AVAILABLE  PLEASE READ

Adapter drivers and setup instructions are found at the bottom of this page

Updates and support are free for 1 year after purchase unless you have an update and support subscription.  please obtain your subscription link from 


The most recent update contains all update changes from previous updates.

Updates require the full version be installed, updates only contain the updated files so do not uninstall, simply run the update.  PF-Diagnose is 32bit but should run on 64 bit systems as no errors were reported when scanned for 64 bit compatibility.  Please refer to the FAQ page for details

 

IMPORTANT UPDATES AVAILABLE

New Versions for the following editions are now available

Basic HD New Version 1.1.0.19 SAE Codes only

FULL HD New Version 1.1.0.19 OEM Faults Database and extra features

Full HD with OBD-II New Version 1.2.0.9 OEM Faults Database Heavy, Medium, and Light duty coverage

 

The above editions have been updated. 

New Fault Codes, New PIDs and New licensing.

 

If you are within your first year of free updates, or have a valid update subscription and have not been notified of this latest update, Or your current installation is no longer registered, please email support for your update link and instructions today!  Please allow 48 hrs to confirm and process your request.

 

Remember, 1.1.0.18 basic can only update to 1.1.0.19 basic


 

1.1.18

Select the version number above to download now, once installed a new key will be required so do not install if your subscription has expired...

  • Updated Fault Codes

  • Updated Executable

  • Database Version July 2010 or newer

 Please email support for the Update Link. You must have a valid support subscription to get this update  Valid Support Subscriptions are if you purchased PF-Diagnose within the past 12 months or you signed up for the annual support and updates subscription

 

Please allow up to 2 business days  for the link to be sent via return email

 

Include your Name in the email to speed up processing time, Thanks!

If your update does not change the file version, please do one of the following

  • Manually install the files by following the instructions in this file MANUAL UPDATE

  • Uninstall using add and remove programs then reinstall the latest full version from HERE


PREVIOUS RELEASES

 

1.1.17e

NEW KEY REQUIRED

 

 

Request new key after installing

Provide Machine ID, Serial Number and Old Key

for faster service

Please allow up to 24hrs to process

  • Changes to registration validation to correct valid key no longer works

  • added Module Filters, now you can filter the modules that you want to read

  • added logo.bmp to install folder, now you can edit the logo on printouts

  • (This is a pre-release of 1.2 and is being released now due to key issues)

 

 

1.1.0.17b

Changes

  • Corrected Lockup in J1939 in Monitor tab on some engines

1.1.0.17

Changes

  • More SPNs displayed for Emissions

  • Emissions Graph

  • More 2010 Codes

  • New Detroit Diesel Support

  • Main Screen easier to read

  • Faster Scan Routines

  • Dual Protocol Support to allow J1708 and J1939 scans at the same time

  • More Com Control Options

This is a full upgrade install and requires a new key.  Once installed, your version will become UNREGISTERED and stop working until you get a new key so we suggest that you upgrade just before the weekend so you have no down time.

 

 

 

1.0.9.24

DOWNLOAD NOW

Changes in this version

  • Corrected Byte Count for J1939 Multiple DTCs may show incorrect or not found DTCs after first DTC is displayed

 

 

1.0.9.23

 

Changes in this version

  • Added Graph Disable checkbox

  • Modified History to distinguish between connections and played recordings

  • Corrected Body Controller Hardware Version did not reset when changing vehicles without restarting

  • When Vehicle Make is learned it now is recorded in Work order screen

  • Corrected Body and other modules caused Lockup if any data was missing from Make Model Serial or Unit numbers in J1939

1.0.9.22 

Changes in this version

  • Corrected J1939 VIN Numbers in some ECMs are longer than 17 characters causing PF-Diagnose to crash.  A new routine corrects this.

  • Adjusted Transmit timing

  • Added Updates to PF-Diagnose drivers for PFDiagnose adapter to connect on J1939 with other software (Compatibility not warranted)

 

1.0.9.21

Changes in this version

  • Corrected J1708 Some PIDs do not show on gauge or graph tab but do show in Monitor tab.  This was caused by a missing value in the tab selection

  • Removed one section of redundant code and added functions to J1708 regular scan code

  • Please reselect your protocol device after updating

 

1.0.9.19

Changes in this version

  • Corrected Parameter Error in J1939 scans with unusual engine Make field

1.0.9.18

Changes in this version

  • Corrected Bars in Data Monitor disappear when switching recorded files

  • Added Check for Updates button and menu item

  • Added more Cummins Fault code definitions

1.0.9.17

Changes in this version

  • Added Trip Totals Tab to display Trip Information

  • Added Reset Trip Totals Menu item to allow resetting trips (J1939 and OEM version ONLY)

  • Corrected Graph item for Boost pressure reads too high

  • Corrected J1939 Crankcase pressure reads too high

  • Added Version Tracking so copies found on pirate sites can be traced to registered owner.

1.0.9.16

 

Changes in this version

  • Updated Emissions Tab to include more Cummins Emissions Parameters

  • Added more 2010 Code descriptions for Cummins

  • Modified Playback so you do not have to exit and restart to play another recording

  • Fixed VIN number display to read from more ECMs

  • Created a smaller Upgrade installer for easier upgrading

  • Modified J1939 Request functions when a checkbox is selected in the data views to request that SPN. Check mark is removed after request is sent to reduce chatter on the datalink.

NOTE: If you get a database error after installing, follow these steps

  • Go to C:\Program Files\Pocketfleet\PFDiagnose

  • Delete the file PID.mdb

  • Re-apply the update by selecting the repair option

Confirm the install by looking at the top message when first running PF-Diagnose, it should read as follows:

Welcome to PF-Diagnose! Database version 1.0.9.16 Date: March 14, 2010


 

1.0.9.15

Changes in this version

  • Added Emissions tab for Emissions control monitoring

  • Added 2010 Code descriptions for Cummins

  • Corrected coolant temperature on gauge did not always match data view

  • Corrected some calculations

  • Modified J1939 SPN to PGN requesting when checking the box next to a SPN

  • Updated J1939 Parameter lists to 2010 levels.


 

1.0.9.14

 

Changes in this version

  • Record changes the file name to the last recorded file during the current session

  • Corrected Check engine and ABS indicator lamps now work in all tabs rather than just in Monitor

  • Corrected Cummins Engine Make details would sometimes appear briefly then vanish from the MAKE box

  • Corrected Freightliner Body Codes in J1708 caused a Database error message of too few parameters


 

1.0.9.12

Email requesting a link to the update.  You must have a registered version. Please allow 2 business days to process the upgrade request.

 

Changes in this version

  • Record and Playback, you can record and then play back an entire session in real time

  • Updated 2010 Codes for Cummins Freightliner and Mercedes

  • Corrected problem with J1939 on Iveco trucks that caused a program halt condition

  • Corrected J1939 showed total key on hours, now shows engine running hours

  • Corrected Check Engine light status so it changes with dash counterparts

  • Updated Manual


 

1.0.9 More Features

  • Added Trans warning Indicator

  • Added base support for CAN, ESCAN and J1850

  • Changed display of drivers to indicate (Unsupported) next to protocols that are not supported

  • Windows 7 Compatible


 

1.0.8 More features

  • Added ABS Lamp Indicator
  • Added More VIN Make definitions
  • Added RP1210 Transmit and receive Indicators (LED Style) Reduced redundant send messages to 1 every 15 seconds from 3 / second Improved buffering When Data PIDs are selected, a call to send is initiated
  • More code definitions
  • Added Make Selection box in Body controller for more accurate multiplex codes
  • Added Engine Make Selection for more accurate engine fault codes
  • Added more SPNs to data view for Tachograph details
  • Added Session Logging
  • Improved code to erase DTCs, sometimes you had to select erase several times before the codes actually erased, now the software checks and resends the command until the module confirms codes are erased.
  • NOTE: Active codes can not be erased and you can not erase codes with the engine running

1.0.6 Security Update caused crash CRITICAL UPDATE


1.0.0 INITIAL Release


Install Instructions

INSTALL INSTRUCTIONS IN WORD FORMAT

NEW INSTALL INSTRUCTIONS IN PDF FORMAT

 

DOWNLOAD

PF-Diagnose Adapter Drivers

 

Prolific Serial to USB Adapter Driver Windows XP

INSTRUCTIONS ON SETUP

 

 OTHER PROLIFIC ADAPTER DRIVERS

Serial to USB Adapter Driver XP 64 Bit

Serial to USB Adapter Driver Vista

Serial to USB Adapter Driver Windows 7

 

Email for a link to the latest version

 

Version Numbers:  A.B.C.D   A=Major Version B=Minor Version C=Sub Version D=Build

Your key is based on the Major plus Minor version A.B

You do not need a new key if the first two numbers of your version matches this update (Primary Version)


 

Upgrade policy

Upgrades are free for 12 months, Any changes to the primary version requires a new key, if you qualify for a free upgrade, email for a new key, please include your transaction number and the title of the software for verification.

Service Packs are always free provided your primary version matches the product you purchased. for example, if you have version 1.1.0.0 any service packs starting with 1.1 are free for you and your key will work for this updated version IE: 1.1.3.566

Feature changes are indicated by a change in the Primary version and may be subject to an upgrade charge after the first 12 months IE: to go from 1.1.3.566 to 1.2.1.0 is considered a feature change and not a fix even if this new version addresses some previous issues as well as added features.

To find out if you qualify for a free upgrade, email

Pocketfleet reserves the right to issue free upgrades regardless of version number at it's sole discretion as a good-will gesture.  Decisions are made on an individual basis and does not constitute a change in policy

 

Copyright (c) 2007, POCKETFLEET SOFTWARE, ALL RIGHTS RESERVED

Last Update:10/10/2009